Installation:
Die-lifters
are fixed in T slot. Die-lifters must be 1 mm below bolster top
in un pressurized mode. Proper packing should
be used to achieve this specific height. Connector tubes are used
to connect two units of die-lifter in the row. End units are
with port at one side & female hole for connector tube at
other end. Minimum two rows of die-lifter are required to balance
die weight.
Operation:
For changing
die, first unclamp the die-set. (Keep all cylinders in Parking
stand, if die is clamped by die clamping cylinders)
Move ram up. Pressurize die-lifter, so that die is lifted by 2mm
above bolster top. Push die-set on trolley. Push new die set on
bolster. Release die-lifter pressure so that die will rest on
bolster.
Notes: