OTHER ELEMENTS

  a. Hydraulic Rotary Coupling

  b. Hydraulic Coupling Unit

  c. Clamping Sleeve 


 

 

 


BALL LATCH
FOR SINGLE MINUTE EXCHANGE OF FIXTURE

 
Ball latch

Ball latch does two functions:
I. Locating       II. Clamping
Locating is achieved by two precision bushes & one locating pin. Screw & balls in tapered seat achieve positive clamping.

 
Ball latch DiagramBall latch Diagram


APPLICATION:

     Ball latch is useful to locate & to clamp fixture plate to base plate in a minute. This system is suitable for CNC machine where
small batches of different jobs are machined. Diagonally opposite two ‘Ball-Latches’ are sufficient to locate plate. Additional
ball latch may create redundant location. Additional ball latch can be used for clamping purpose without fixing liner bushes.
A. For accurate repeatability (±0.013mm), use two primary liner & center distance tolerance for hole machining is ±0.005mm.
     (Fig. A)
B. For slightly less accurate repeatability (±0.04 mm) use one primary & one secondary liner with center distance Tolerance
     for hole machining ±0.025mm (Fig. B)

For Repeatability ±0.013mm.
clamp fixture plate
clamp fixture plate
For Repeatability ±0.013mm.

VERSIONS:


Ball latch has three parts: -

  •  Shank - Shank are available in 16mm, 20mm & 25 mm sizes.
  •  Liner - Liner bushes have two types. Primary Liners are with close tolerance, while secondary
      liners  are slighth loose.
  •  Bottom Bush - Bottom bushs are of two types. Bolt in bushes are fixed from front side, while
      reverse  fit bushes are pressed from bottom side.
    Moulting Method With
Bolt-in Recessed BushMoulting Method With
Bolt-in Recessed BushMoulting Method With
Reverse Mount Bush
    Moulting Method With
Bolt-in Recessed BushMoulting Method With
Bolt-in Recessed Bush
    Moulting Method With
    Bolt-in Recessed Bush
    Moulting Method With
    Reverse Mount Bush


    IMPORTANT NOTES:

  •  Never use more than two liner in the fixture plate. Additional clamping holes must be without liners.
  •  While pressing reveres mount bush interference should not be more than 0.013mm.
  •  Bolt in bushes should be below the surface.

^TOP      

Copyright © 2005 Hy-Power Clamps Pvt. Ltd. All rights reserved.